Özet
Zero-valent iron (ZVI)-and zero-valent aluminium (ZVA)-Activated persulfate (PS) oxidation procedure was applied to remove the industrial pollutants 3,5-dichlorophenol (3,5-DCP; 12.27 uM) and 2,4-dichloroaniline (2,4-DCA; 12.34 uM) from aqueous solutions. The effects of PS concentration and pH were investigated to optimize heterogeneous treatment systems. Negligible removals were obtained for both pollutants by individual applications of nanoparticles (1 g/L) and PS (1.00 mM). PS activation with ZVI resulted in 59% (1.00 mM PS; 1 g/L ZVI; pH 5.0; 120 min) and 100% (0.75 mM PS; 1 g/L ZVI; pH 5.0; 80 min) 3,5-DCP and 2,4-DCA removals, respectively. The ZVA/PS treatment system gave rise to only 31% 3,5-DCP (1.00 mM PS; 1 g/L ZVA; pH 3.0; 120 min) and 47% 2,4-DCA (0.25 mM PS; 1 g/L ZVA; pH 3.0; 120 min) removals. The pH decreases from 5.0 to 3.0 and from 3.0 to 1.5 enhanced contaminant removals for ZVI/PS and ZVA/PS treatments, respectively. Pollutant removal rates were in correlation with the consumption rates of the oxidants. Metal ion (Al, Fe) release increased in the presence of PS and with decreasing pH.
Orijinal dil | İngilizce |
---|---|
Sayfa (başlangıç-bitiş) | 269-281 |
Sayfa sayısı | 13 |
Dergi | Turkish Journal of Chemistry |
Hacim | 45 |
Basın numarası | 2 |
DOI'lar | |
Yayın durumu | Yayınlandı - 2021 |
Bibliyografik not
Publisher Copyright:© 2021 TUBITAK. All rights reserved.
Finansman
The study was financially supported by İstanbul Technical University under the project no. MDK-2019-42052.
Finansörler | Finansör numarası |
---|---|
Istanbul Teknik Üniversitesi | MDK-2019-42052 |