Ana gezinime geç Aramaya geç Ana içeriğe geç

Time-Dependent Passive Building Thermography for Detecting Delamination of Adhered Ceramic Cladding

  • Ecem Edis*
  • , Inês Flores-Colen
  • , Jorge De Brito
  • *Bu çalışma için yazışmadan sorumlu yazar
  • University of Lisbon

Araştırma sonucu: Dergiye katkıMakalebilirkişi

19 Atıf (Scopus)

Özet

Time-dependent passive infrared thermography (td-PIRT) is an inspection technique that can be used to detect delamination. td-PIRT was used to inspect two buildings in Lisbon (Portugal) with adhered ceramic cladding to evaluate its potential to detect delamination problems in such claddings, which is a common problem and has safety risks. The td-PIRT data were analysed quantitatively by means of simple image subtraction (SIS), nonnegative matrix factorisation (NMF), and principal component analysis (PCA). Comparative evaluations showed that td-PIRT has a great potential to detect delamination problems in adhered ceramic cladding, depending on the analysis method selected. PCA and NMF were found to be efficient methods because of their good, consistent performance in revealing defective areas.

Orijinal dilİngilizce
Makale numarası24
DergiJournal of Nondestructive Evaluation
Hacim34
Basın numarası3
DOI'lar
Yayın durumuYayınlandı - 30 Ağu 2015

Bibliyografik not

Publisher Copyright:
© 2015, Springer Science+Business Media New York.

Finansman

The authors thank the IST-DECivil Building Construction group and ICIST and ISTAR for allowing the use of equipment. The first author acknowledges the financial support of ITU and TUBITAK for the research visit.

Finansörler
TUBITAK
International Technological University

    Parmak izi

    Time-Dependent Passive Building Thermography for Detecting Delamination of Adhered Ceramic Cladding' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap