Özet
This paper deals with a new method of evaluating lightning impulse voltage parameters. For this purpose, three different types of impulse signals were used for analysis. The main point of the study focuses on the k-factor and wavelet transform methods to attenuate oscillations and overshoots that occur in impulse voltages. In this manner, as an alternative method to the k-factor approach, which is proposed in the IEC Standard 60060-1, the wavelet-based filtering approach is presented and its last approximation sub-band is described as de-noised data. Under the comparisons of the calculated signal parameters, the wavelet application was found to be a powerful method as much as the k-factor filtering in terms of a mathematical solution to the related problem.
Orijinal dil | İngilizce |
---|---|
Sayfa (başlangıç-bitiş) | 2843-2852 |
Sayfa sayısı | 10 |
Dergi | Arabian Journal for Science and Engineering |
Hacim | 43 |
Basın numarası | 6 |
DOI'lar | |
Yayın durumu | Yayınlandı - 1 Haz 2018 |
Bibliyografik not
Publisher Copyright:© 2017, King Fahd University of Petroleum & Minerals.