The influence of the attachment type and implant number supporting mandibular overdentures on stress distribution: An in Vitro study, part i

Selda Arat Bilhan, Hakan Bilhan*, Ergun Bozdag, Emin Sunbuloglu, Cengiz Baykasoglu, Omer Kutay

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Dergiye katkıMakalebilirkişi

10 Atıf (Scopus)

Özet

OBJECTIVES: The main goal of this study was to compare the stress distribution of mandibular overdentures (OVD) with different numbers of supporting implants and single versus splinted attachment types. MATERIALS AND METHODS: Four different biting situations were simulated for the 2-, 3-, and 4-implant retentive anchor as well as bar attachment OVDs on a formalin-fixed cadaver mandible, and strains were recorded under vertical loading of 100 N. RESULTS: The calculated von Mises values from measured strains in all measurement sites and loading conditions for nonsplinted attachments (retentive anchor) were higher than splinted (bar) attachments. CONCLUSIONS: It may be concluded that in cases with low quality and quantity of bone, the increase in number of implants and the use of a splinted attachment should be preferred to reduce forces emerging around the implants during function. The use of 2 single attachments in cases with good bone quality and ideal size implants still seems to be a safe and sufficient solution for the treatment of mandibular edentulism with OVDs.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)39-48
Sayfa sayısı10
DergiImplant Dentistry
Hacim22
Basın numarası1
DOI'lar
Yayın durumuYayınlandı - Şub 2013

Parmak izi

The influence of the attachment type and implant number supporting mandibular overdentures on stress distribution: An in Vitro study, part i' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap