This study was conducted to evaluate the effect of TiO2 + MnO2 and MgO + Cr2O3 additions on the wear resistance of alumina based ceramic nozzles sintered at 1550°C for 1 h. Wear performance of the nozzles was determined by recording their weight loss during electrostatic enameled coating process. When compared to pure alumina nozzles, 0.5% MgO + 1.2% Cr2O3 addition improved the wear resistance by about 35%.
Orijinal dil | İngilizce |
---|---|
Sayfa (başlangıç-bitiş) | 805-808 |
Sayfa sayısı | 4 |
Dergi | Key Engineering Materials |
Hacim | 264-268 |
Basın numarası | II |
DOI'lar | |
Yayın durumu | Yayınlandı - 2004 |
Etkinlik | Proceedings of the 8th Conference and Exhibition of the European Ceramic Society - Istanbul, Turkey Süre: 29 Haz 2003 → 3 Tem 2003 |