THE EFFECT OF LAP-SPLICE CONFIGURATION ON SEISMIC PERFORMANCE OF SUBSTANDARD RC COLUMNS

A. Baltaci, S. Gundogan, U. Demir, A. Ilki

Araştırma sonucu: ???type-name???Konferans katkısıbilirkişi

Özet

A considerable amount of existing reinforced concrete (RC) buildings in developing countries possess vital deficiencies such as incorporating poor quality of concrete and insufficient transverse reinforcement, and use of plain reinforcing bars without proper detailing, such as inadequate configurations of lap-splices at critical plastic hinging zones. While these can affect the strength and ductility of structural members adversely under seismic actions, research on such substandard structural members is scarce. As such, further information is valuable for the assessment of the seismic safety of such substandard columns constructed with inadequate lap-splice configurations of plain round bars. Therefore, this study aims to investigate the effects of different lap-splice configurations of plain bars on the seismic performance of substandard RC columns and contribute to the development of assessment codes for such existing substandard buildings. Towards this aim, three full-scale columns were constructed to represent typical characteristics of substandard RC columns. The columns were subjected to constant axial loading (with an axial load to capacity ratio of 0.3) and reversed cyclic displacement reversals simultaneously representing gravity loads and seismic actions, respectively. The test program included i) one reference column with continuous longitudinal bars (no lap-spliced connection), ii) one lap-spliced column with an overlap length of 20 times the longitudinal bar diameter without any hook and iii) one lap-spliced column with an overlap length of 20 times the longitudinal bar diameter with a 180-degree hook. Test results demonstrated that columns with lap-splices did not reach their flexural strength and experienced more remarkable strength degradation with respect to the column reinforced with continuous longitudinal bars. On the other hand, presence of a 180-degree hook at the ends of spliced bars reduced the negative influence of inadequate lap-splice length in terms of strength and ductility.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıProceedings for the 6th fib International Congress, 2022- Concrete Innovation for Sustainability
EditörlerStine Stokkeland, Henny Cathrine Braarud
Yayınlayanfib. The International Federation for Structural Concrete
Sayfalar1573-1582
Sayfa sayısı10
ISBN (Basılı)9782940643158
Yayın durumuYayınlandı - 2022
Etkinlik6th fib International Congress on Concrete Innovation for Sustainability, 2022 - Oslo, Norway
Süre: 12 Haz 202216 Haz 2022

Yayın serisi

Adıfib Symposium
ISSN (Basılı)2617-4820

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???6th fib International Congress on Concrete Innovation for Sustainability, 2022
Ülke/BölgeNorway
ŞehirOslo
Periyot12/06/2216/06/22

Bibliyografik not

Publisher Copyright:
© Fédération Internationale du Béton – International Federation for Structural Concrete.

Parmak izi

THE EFFECT OF LAP-SPLICE CONFIGURATION ON SEISMIC PERFORMANCE OF SUBSTANDARD RC COLUMNS' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap