Ana gezinime geç Aramaya geç Ana içeriğe geç

Sintering effects on mechanical properties of biologically derived dentine hydroxyapatite

  • Gültekin Göller*
  • , Faik Nüzhet Oktar
  • *Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Dergiye katkıMakalebilirkişi

79 Atıf (Scopus)

Özet

In this study, the change in the mechanical properties of hydroxyapatite (HA), which is the main mineral content of bone and teeth, commonly used as an implant material, is tested for different sintering temperatures. Although HA shows great biocompatibility with the human body, its applications are limited to non-load-bearing areas and coatings due to its low mechanical properties. These mechanical properties can be improved substantially by sintering. In this study, naturally produced HA from human teeth is sintered, and density, microhardness measurements and compression tests are performed in order to find the optimum sintering temperature. The results are compared with the synthetically derived HA properties from the literature.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)142-147
Sayfa sayısı6
DergiMaterials Letters
Hacim56
Basın numarası3
DOI'lar
Yayın durumuYayınlandı - Eki 2002

Parmak izi

Sintering effects on mechanical properties of biologically derived dentine hydroxyapatite' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap