Özet
The improvement of mechanical properties of HA with reinforcement of 5 and 10 wt % bioglass (45S5) with different sintering temperatures was studied. Although HA shows good biocompatibility with human body, its applications are limited to nonload-bearing areas due to its low mechanical properties. In this study naturally produced HA from human teeth is sintered with varying addition of 5 wt % and 10 wt % bioglass at 1200 and 1300°C for 4 hours. The density, microhardness measurements and compressive tests are performed and microstructural characterizations are carried out in order to find the optimum sintering temperature. Finally average hardness value of 383±60 HV (kg/mm2), average density of 2.72±0.01g/cm3, and compressive strength value of σavr=82.96±34 MPa were achieved by sintering at 1200°C with the addition of 10 wt % bioglass in HA.
| Orijinal dil | İngilizce |
|---|---|
| Sayfa (başlangıç-bitiş) | 939-942 |
| Sayfa sayısı | 4 |
| Dergi | Key Engineering Materials |
| Hacim | 240-242 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - 2003 |
| Etkinlik | Proceedings of the 15th International Symposium on Ceramics in Medicine; The Annual Meeting of the International Society for Ceramics in Medicine - Sydney, NSW, Australia Süre: 4 Ara 2002 → 8 Ara 2002 |
Parmak izi
Sintering effects on mechanical properties of bioglass reinforced hydroxyapatite composites' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.Alıntı Yap
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver