Ana gezinime geç Aramaya geç Ana içeriğe geç

Simultaneous determination of six nitrosamines in different pharmaceutical dosage forms by GC–MS/MS with headspace module vs. autosampler solvent vent mode: Development and validation

  • Hayriye İçin*
  • , Hasan Tünel
  • , Hakan Akbıyık
  • , G. G. Kayar
  • , Nevin Öztekin
  • *Bu çalışma için yazışmadan sorumlu yazar
  • Istanbul Technical University
  • Abdi Ibrahim Pharmaceuticals

Araştırma sonucu: Dergiye katkıMakalebilirkişi

Özet

The determination of N-nitrosamines is of significant importance in pharmaceutical drug products. An analytical method was devised and validated in this study to accurately and easily determine nitrosamines, thereby eliminating the interfering matrix effect in various pharmaceutical forms. N-nitrosodiethylamine (NDEA), N-nitrosodimethylamine (NDMA), N-nitrosodiisopropylamine (NDIPA), N-nitrosomethylphenylamine (NMPA), N-nitrosoisopropylethylamine (NEIPA), and N-nitrosodibutylamine (NDBA) were quantified in the suspension, emulsion, and tablet pharmaceutical forms. The concentration range was adjusted from the quantification limit (QL) to the upper limit of quantification (ULOQ). The limit concentration levels were calculated according to acceptable daily intake of each product and daily limits of N-nitrosamines which mentioned in FDA guidance. The concentration limits were defined to be 1.92 ng/mL, 0.53 ng/mL, 8.0 ng/mL, 30.0 ng/mL, 2.0 ng/mL and 0.53 ng/mL, respectively, for each N-nitrosamines. The method validation was successfully applied with an acceptable linearity (R2 > 0.99), accuracy (recovery range is 79.5–122.4 %) and precision (RSD < 15.0 %). During the analysis, a Gas Chromatography (GC) system with an MS/MS detector and a Headspace (HS) module was employed, equipped with a VF-WAXMS capillary column (30 m × 0.25 mm × 1 μm). The results obtained were compared with a validated GC–MS/MS Autosampler method with solvent vent mode.

Orijinal dilİngilizce
Makale numarası124792
DergiJournal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
Hacim1267
DOI'lar
Yayın durumuYayınlandı - 15 Ara 2025

Bibliyografik not

Publisher Copyright:
© 2025 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.

Parmak izi

Simultaneous determination of six nitrosamines in different pharmaceutical dosage forms by GC–MS/MS with headspace module vs. autosampler solvent vent mode: Development and validation' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap