Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry

  • Sabriye Sel
  • , Elif Öztürk Er
  • , Sezgin Bakırdere*
  • *Bu çalışma için yazışmadan sorumlu yazar
  • Yildiz Technical University

Araştırma sonucu: Dergiye katkıMakalebilirkişi

11 Atıf (Scopus)

Özet

A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90–105% in tap water and 94–97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)4740-4746
Sayfa sayısı7
DergiJournal of Separation Science
Hacim40
Basın numarası24
DOI'lar
Yayın durumuYayınlandı - Ara 2017
Harici olarak yayınlandıEvet

Bibliyografik not

Publisher Copyright:
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Finansman

The authors thank Science and Technology Application and Research Center of Yıldız Technical University for instrumental analysis support. In addition, authors thank Yıldız Technical University for the financial support (Scientific Research Project, 2015-01-02-YL08).

FinansörlerFinansör numarası
Yildiz Teknik Üniversitesi2015-01-02-YL08

    BM SKH

    Bu sonuç, aşağıdaki Sürdürülebilir Kalkınma Hedefine/Hedeflerine katkıda bulunur

    1. SKH 6 - Temiz Su ve Sanitasyon
      SKH 6 Temiz Su ve Sanitasyon

    Parmak izi

    Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap