Ana gezinime geç Aramaya geç Ana içeriğe geç

Seismic Performance of Substandard RC Columns Retrofitted with Sprayed GFRM

  • Nima Kian*
  • , Ugur Demir
  • , Cem Demir
  • , Muhammed Marasli
  • , Alper Ilki
  • *Bu çalışma için yazışmadan sorumlu yazar
  • Istanbul Technical University
  • Izmir Institute of Technology
  • Fibrobeton Company

Araştırma sonucu: Kitap/Rapor/Konferans Bildirisinde BölümKonferans katkısıbilirkişi

3 Atıf (Scopus)

Özet

There is a myriad amount of substandard reinforced concrete (RC) buildings in developing countries that do not comply with the requirements and instructions of the current building design codes. In particular, columns in these substandard buildings demonstrate unsatisfactory and undesired behavior against lateral loads, mainly due to low concrete compressive strength and poor reinforcement detailing. The problem is exacerbated when the axial load ratio (ratio of applied axial load to the axial load capacity) and/or the shear ratio (ratio of shear force corresponding to moment capacity (Ve) to the shear capacity (Vr)) is/are high, leading to brittle failure modes. In this study, three full-scale substandard RC columns subjected to high axial load ratio of 0.75 were tested under constant axial load combined with reversed cyclic lateral displacements. Shear ratio (Ve/Vr) of the substandard columns were 0.75 and 0.82 according to ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and (Turkish Building Earthquake Code (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), respectively. According to the TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), columns had a high Ve/(fctmbd) ratio of 1.12, where, fctm, b, and d are the direct tensile strength of concrete, width of the cross-section, and effective depth of the section. The ratio of transverse reinforcement to minimum required transverse reinforcement according to the ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey) was 0.19 and 0.77, respectively. Two of the columns were retrofitted with an innovative, cost-effective, and easily-applicable strengthening method, through external jacketing with sprayed glass fiber reinforced mortar (GFRM) of different characteristics. The remaining column was tested as the reference specimen to evaluate the efficiency of the strengthening method. The test results demonstrated the extremely poor performance of the reference substandard column as well as the remarkable lateral load capacity and ductility improvement provided by the adopted novel strengthening approach.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığı10th International Conference on FRP Composites in Civil Engineering - Proceedings of CICE 2020/2021
EditörlerAlper Ilki, Medine Ispir, Pinar Inci
YayınlayanSpringer Science and Business Media Deutschland GmbH
Sayfalar1317-1328
Sayfa sayısı12
ISBN (Basılı)9783030881658
DOI'lar
Yayın durumuYayınlandı - 2022
Etkinlik10th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering, CICE 2021 - Virtual, Online
Süre: 8 Ara 202110 Ara 2021

Yayın serisi

AdıLecture Notes in Civil Engineering
Hacim198 LNCE
ISSN (Basılı)2366-2557
ISSN (Elektronik)2366-2565

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???10th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering, CICE 2021
ŞehirVirtual, Online
Periyot8/12/2110/12/21

Bibliyografik not

Publisher Copyright:
© 2022, The Author(s), under exclusive license to Springer Nature Switzerland AG.

Finansman

Acknowledgments. This research was granted in the scope of the bilateral collaboration between the research councils of Turkey (TUBITAK) and the United Kingdom (RCUK) under the grant number 216M379. The authors are most thankful to the Fibrobeton company for their continuous support from the construction phase of the specimens to the testing stage. The contributions of Furkan Narlitepe, Merve Nur Demir, Alihan Baltaci, Muhsin Can Luleci, Bilal Sari, Safiye Gundogan, Erkan Tore and summer trainees are gratefully acknowledged.

FinansörlerFinansör numarası
Research Councils UK216M379

    BM SKH

    Bu sonuç, aşağıdaki Sürdürülebilir Kalkınma Hedefine/Hedeflerine katkıda bulunur

    1. SKH 1 - Yoksulluğa Son
      SKH 1 Yoksulluğa Son

    Parmak izi

    Seismic Performance of Substandard RC Columns Retrofitted with Sprayed GFRM' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap