Seismic performance of a full-scale frp retrofitted sub-standard RC building

Alper Ilki*, Erkan Tore, Cem Demir, Mustafa Comert

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: ???type-name???Bölümbilirkişi

7 Atıf (Scopus)

Özet

External jacketing of columns with Fiber Reinforced Polymers (FRPs) is a promising retrofitting technique for improving seismic performance of sub-standard reinforced concrete (RC) buildings. The enhancement in deformation capacity and shear strength of jacketed members helps to prevent the brittle collapse mechanism of buildings with inadequate ductility. This paper provides an overview on the retrofitting of columns with FRP jacketing for particularly ductility enhancement and gives a brief summary of seismic strengthening recommendations of various design documents. In addition, a recent full-scale test conducted simultaneously on an as-built and a FRP retrofitted building, which are identical with design geometry, material quality and seismic deficiencies, is briefly presented and the performance of the retrofitting technique is evaluated. Finally, analytical behavior obtained through nonlinear static analyses executed using FRP-confined concrete models recommended in different technical documents are reviewed in comparison with the experimental behavior.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıGeotechnical, Geological and Earthquake Engineering
YayınlayanSpringer Netherlands
Sayfalar519-544
Sayfa sayısı26
DOI'lar
Yayın durumuYayınlandı - 2018

Yayın serisi

AdıGeotechnical, Geological and Earthquake Engineering
Hacim46
ISSN (Basılı)1573-6059
ISSN (Elektronik)1872-4671

Bibliyografik not

Publisher Copyright:
© Springer International Publishing AG, part of Springer Nature 2018.

Finansman

Authors are thankful to DowAksa Advanced Composites Holding B.V. and Governorship of Yalova for various supports provided for experimental studies. The contributions of Ilgaz Doğan (DowAksa), Çağlar Göksu Akkaya (PhD, ITU), Pınar İnci (PhD Cand., ITU), Ergün Binbir (PhD Cand., ITU), Ali Osman Ateş (PhD Cand., ITU), Ali Naki Şanver (MSc Cand., Rise Eng.), Çağlar Üstün (MSc Cand., RISE Eng.), Duygu Çakır (Civil Eng., Rise Eng.), Gökhan Sarı (Undergrad., Balıkesir University), Emin Amini (Undergrad., Balıkesir University), Tamer Şahna (Undergrad., Balıkesir University), Oğuzhan Sözer (Undergrad., Balıkesir University), Berkay Aldırmaz (MSc Cand., ITU), Ömer Faruk Halıcı (MSc, ITU), Mehmet Aksa (Undergrad., Kultur Uni.) are also gratefully acknowledged.

FinansörlerFinansör numarası
Balikesir Üniversitesi

    Parmak izi

    Seismic performance of a full-scale frp retrofitted sub-standard RC building' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap