Seismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete

  • Idris Bedirhanoglu*
  • , Alper Ilki
  • , Thanasis C. Triantafillou
  • *Bu çalışma için yazışmadan sorumlu yazar
  • New York University
  • Dicle University
  • University of Patras

Araştırma sonucu: Dergiye katkıMakalebilirkişi

37 Atıf (Scopus)

Özet

Short columns with deficiencies of low-strength concrete and large spacing of transverse reinforcement are quite common in construction practice in many developing countries in seismically active regions. Therefore, it is important to retrofit this type of column to avoid negative consequences in the case of severe damage. External fiber-reinforced polymer (FRP) jacketing is one of the most practical methods to retrofit reinforced concrete (RC) frame members against shear actions. However, knowledge of the seismic behavior of FRP-retrofitted RC short columns is still limited. Thus, the aim of this study was to investigate the seismic response of FRP-retrofitted low-strength RC short columns with and without predamage through the testing of 11 short column specimens representing old and deficient RC buildings. Accordingly, the results of a research program on the seismic behavior of such columns and on their repair and FRP retrofitting, covering experimental and analytical phases, are presented. In the experimental phase, test results obtained for short columns, FRP-retrofitted short columns, and repaired and retrofitted short columns are documented. Test results provide important knowledge about the effects of extremely low-strength concrete, and of different levels of predamage on the behavior of FRP-retrofitted substandard short columns. In the analytical phase, the performance of relevant design documents in predicting the shear strength of such columns retrofitted with FRP jacketing was tested through the comparison of predicted and experimental results.

Orijinal dilİngilizce
Makale numarası04021068
DergiJournal of Composites for Construction
Hacim26
Basın numarası1
DOI'lar
Yayın durumuYayınlandı - 1 Şub 2022

Bibliyografik not

Publisher Copyright:
© 2021 American Society of Civil Engineers.

Finansman

The authors express their grateful thanks to I.H. Basegmez, D. Akgun, Y. Candan, O. Incecik, and C. Demir for their assistance during tests. The BASF chemical company provided the repair and retrofitting materials. Thanks are due to TUBITAK (The Scientific and Technological Research Council of Turkey) for providing the grants to continue this research at Purdue University.

Finansörler
TUBITAK
Purdue University
Türkiye Bilimsel ve Teknolojik Araştirma Kurumu

    Parmak izi

    Seismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap