Ana gezinime geç Aramaya geç Ana içeriğe geç

Reduction behaviors of chromite and nio in liquid FE-C alloys

Araştırma sonucu: Kitap/Rapor/Konferans Bildirisinde BölümKonferans katkısıbilirkişi

2 Atıf (Scopus)

Özet

In this study, reduction behaviours of Turkish chromite concentrate (48 % Cr 2O 3, 13.30 % FeO, 18.33 % MgO, 12.37 % Al 2O 3, 5.76 % SiO 2) and nickel oxide by Fe-C alloy in graphite crucible were investigated. In the first stage of experiments, steel scraps were melted in graphite crucibles and were saturated with carbon at 1600 °C and 30 min. In the second stage, mixtures of different amount of chromite concentrate, nickel oxide and flux additives (CaO, SiO 2 and CaF 2) were charged into the graphite crucible containing the Fe-C alloy and heated to 1600 °C for different reduction times (0-180 min) under argon gas. The highest Cr and Ni contents in alloys were found as 11.41 and 14.37 % and the highest Cr and Ni recoveries were found as 88 and 94 %, respectively at 180 min.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıInnovations In The Ferro Alloy Industry - Proceedings of the XI International Conference on Innovations in the Ferro Alloy Industry, Infacon XI
Sayfalar93-98
Sayfa sayısı6
Yayın durumuYayınlandı - 2007
Etkinlik11th International Conference on Innovations in the Ferro Alloy Industry, Infacon XI - New Delhi, India
Süre: 18 Şub 200721 Şub 2007

Yayın serisi

AdıInnovations In The Ferro Alloy Industry - Proceedings of the XI International Conference on Innovations in the Ferro Alloy Industry, Infacon XI

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???11th International Conference on Innovations in the Ferro Alloy Industry, Infacon XI
Ülke/BölgeIndia
ŞehirNew Delhi
Periyot18/02/0721/02/07

Parmak izi

Reduction behaviors of chromite and nio in liquid FE-C alloys' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap