Özet
Dehydration is one of the most profound physiological challenges that significantly affects athletes and soldiers if not detected early. Recently, a few groups have focused on dehydration detection using sweat as the main biomarker. Although there are some proposed devices, the electrical and chemical characteristics of sweat have yet to be incorporated into the validations. In this work, we have developed a simple test setup to analyze artificial sweat that is comprised the main components of human sweat. We provide theoretical and experimental details on the electrical and chemical behavior of the artificial sweat for various concentration values within a temperature range of 5 °C to 50 °C. We have also developed an efficient sweat collecting and detection system based on 3D printing. Human studies were conducted and this particular protocol has shown that dehydration starts to take effect as early as 40 min into the physical activity if there is no fluid intake during the exercise. We believe that our device will lead to developing viable real-time sweat analysis systems.
| Orijinal dil | İngilizce |
|---|---|
| Makale numarası | 133702 |
| Dergi | Applied Physics Letters |
| Hacim | 106 |
| Basın numarası | 13 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - 30 Mar 2015 |
| Harici olarak yayınlandı | Evet |
Bibliyografik not
Publisher Copyright:© 2015 AIP Publishing LLC.
Parmak izi
Real-time sweat analysis via alternating current conductivity of artificial and human sweat' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.Alıntı Yap
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver