Radiation shielding properties of poly (methyl methacrylate) / colemanite composite for the use in mixed irradiation fields of neutrons and gamma rays

Tayfun Bel, Cuneyt Arslan, Nilgun Baydogan*

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: ???type-name???Makalebilirkişi

68 Atıf (Scopus)

Özet

Poly(methyl methacrylate) (PMMA) was reinforced by using colemanite Ca2B6O11·5H2O (CMT) to increase the radiation shielding capacity of the polymer composite. CMT reinforcement effect was examined at four different CMT concentration levels (such as 5, 15, 30 and 40 wt. %) to investigate radiation protective shielding properties of PMMA/CMT composite. The effect of the CMT reinforcement on the radiation shielding capacity was determined to use the composite at the mixed fields of neutrons and gamma rays. For this purpose, the polymer composite samples were prepared by using in-situ polymerization with atom transfer radical polymerization (ATRP) technique. Radiation shielding capacity was experimentally assessed by using gamma and neutron attenuation tests. The gamma-ray shielding capacity of the composite was examined by using Cs-137 radioisotope and the experimental results of gamma transmittance were compared with theoretical calculations by using WinXCOM. Neutron transmission tests were performed by using a neutron howitzer (239Pu–Be neutron source). Radiation shielding performance of PMMA/CMT composite was examined by the determination of the attenuation coefficient (μ) and the half-value layer (HVL). CMT reinforcement of PMMA supported to increase the radiation shielding capacity by 11.1% for gamma photons of Cs-137 radioisotope and 38.56% for neutrons emitted from Pu–Be neutron source.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)58-67
Sayfa sayısı10
DergiMaterials Chemistry and Physics
Hacim221
DOI'lar
Yayın durumuYayınlandı - 1 Oca 2019

Bibliyografik not

Publisher Copyright:
© 2018 Elsevier B.V.

Finansman

The authors wish to thank TÜBITAK ( The Scientific and Technical Research Council of Turkey ) for financial support with TUBITAK - 1001 Project (project no: 115R017 ). at the several researches of this study. Tayfun BEL would like to thank BIDEB (Bilim Insanı Destekleme Daire Baskanlıgı) 2211-C program of TUBITAK in Turkey.

FinansörlerFinansör numarası
TUBITAK
Türkiye Bilimsel ve Teknolojik Araştirma Kurumu115R017

    Parmak izi

    Radiation shielding properties of poly (methyl methacrylate) / colemanite composite for the use in mixed irradiation fields of neutrons and gamma rays' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap