Özet
Objective: Redirecting of a laterally misplaced pedicle screw into the accurate position decreases the pull-out strength due to the reinsertion, lateral wall cortical perforation and widening of the pedicle hole. Thus, this biomechanical study was performed to quantitatively analyze the pullout strength of a redirected laterally misplaced pedicle screw into the accurate position. Methods: Thirty pedicules of 15 bovine vertebrae were separated to 3 groups, according to the screw placement method: 1) standard flawless trajectory; 2) trajectory with lateral pedicle wall perforation; 3) trajectory with lateral wall perforation redirected to the standard trajectory. Samples were placed on a universal testing machine and pullout loads were measured. Kruskal-Wallis test was utilized within 95% confidence interval and p value <0.05 to test for the statistical significance. Results: The mean pullout strength was 2891±654,2 N(1383-3814,5) in Group 1; 817,8±227,6 N(308,6-1144,9) in Group 2 and 2081,1±487,7 N(1583,5-2962,5) in Group 3. The results found out to be statistically significant (p<0.05). Inter-group comparisons revealed that lateral pedicle wall perforation significantly decreases the pullout strength (p<0.05) and redirection of the screw increases the strength (p<0.05), however it was still weaker than the screws with flawless standard trajectory but this was not statistically significant (p>0.05). Conclusion: The results of this study confirm that pullout strength of pedicle screw decreases by approximately 71% when the lateral wall is perforated and decreases 28% after redirection to the accurate position.
| Orijinal dil | İngilizce |
|---|---|
| Sayfa (başlangıç-bitiş) | 459-463 |
| Sayfa sayısı | 5 |
| Dergi | Acta Orthopaedica et Traumatologica Turcica |
| Hacim | 52 |
| Basın numarası | 6 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - Kas 2018 |
Bibliyografik not
Publisher Copyright:© 2018 Turkish Association of Orthopaedics and Traumatology
Parmak izi
Quantitative comparison of a laterally misplaced pedicle screw with a re-directed screw. How much pull-out strength is lost?' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.Alıntı Yap
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver