TY - JOUR
T1 - Performance improvement methods for quartz tube solid particle fluidized bed solar receiver
AU - BÖLÜK, Mehmet
AU - Şentürk Lüle, Senem
N1 - Publisher Copyright:
© 2022. Yıldız Technical University. All Rights Reserved.
PY - 2022
Y1 - 2022
N2 - The conditions to improve performance of quartz tube silicon carbide (SiC) solid particle fluidized bed solar receiver was investigated with computational fluid dynamics (CFD) simulations. The difficulty of experimenting all possible operating conditions was overcome by preparing CFD base input with appropriate models and parameters. The amount of SiC in the bed, the size of particles, and the air inlet velocity were considered as variables. After model verification, in order to evaluate the effect of particle addition, bed without solid particles were simulated first. Outlet temperature of single-phase receiver was calculated as 421 K. Outlet temperatures of 913 K, 895 K, and 881 K were obtained for 400 µm diameter particles in 0.3 m bed height for air inlet velocities of 0.25, 0.3, and 0.35 m/s. Air outlet temperature decreases as air inlet velocity increases. On the other hand, too much reduction at inlet velocity retards the system performance since it affects fluidization. For 400 gm particle diameter and bed height of 0.2 m, outlet temperatures of 994 K, 974 K, and 955 K were found for the same air inlet velocities above. As bed height decreases, air outlet temperature increases. For particle diameters of 300 and 500 µm for bed height of 0.3 m, outlet temperatures of 980 K and 878 K were calculated for appropriate minimum fluidization velocities. Outlet temperature increased with decreasing particle size.
AB - The conditions to improve performance of quartz tube silicon carbide (SiC) solid particle fluidized bed solar receiver was investigated with computational fluid dynamics (CFD) simulations. The difficulty of experimenting all possible operating conditions was overcome by preparing CFD base input with appropriate models and parameters. The amount of SiC in the bed, the size of particles, and the air inlet velocity were considered as variables. After model verification, in order to evaluate the effect of particle addition, bed without solid particles were simulated first. Outlet temperature of single-phase receiver was calculated as 421 K. Outlet temperatures of 913 K, 895 K, and 881 K were obtained for 400 µm diameter particles in 0.3 m bed height for air inlet velocities of 0.25, 0.3, and 0.35 m/s. Air outlet temperature decreases as air inlet velocity increases. On the other hand, too much reduction at inlet velocity retards the system performance since it affects fluidization. For 400 gm particle diameter and bed height of 0.2 m, outlet temperatures of 994 K, 974 K, and 955 K were found for the same air inlet velocities above. As bed height decreases, air outlet temperature increases. For particle diameters of 300 and 500 µm for bed height of 0.3 m, outlet temperatures of 980 K and 878 K were calculated for appropriate minimum fluidization velocities. Outlet temperature increased with decreasing particle size.
KW - Computational Fluid Dynamics
KW - Concentrated Solar System
KW - Solid Particle Receiver
KW - Two Phase Flow
UR - http://www.scopus.com/inward/record.url?scp=85135508658&partnerID=8YFLogxK
U2 - 10.18186/thermal.1145424
DO - 10.18186/thermal.1145424
M3 - Article
AN - SCOPUS:85135508658
SN - 2148-7847
VL - 8
SP - 477
EP - 489
JO - Journal of Thermal Engineering
JF - Journal of Thermal Engineering
IS - 4
ER -