Operational problems in small wastewater treatment plants: A case study

Süreyya Meriç*, Deniz Kaptan, Süleyman Övez, H. Eser Okten

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: ???type-name???Makalebilirkişi

4 Atıf (Scopus)

Özet

This study was designed to evaluate the present status of Silivri small-scale wastewater treatment plant considering the effluent quality to meet the receiving water standards in Turkey. The basic focus was to rehabilitate the system in terms of microbiological dynamics which may cause basic operational problems in treatment plants. Two procedures were applied in the plant. Increasing oxygen concentration in the areation basins could improve the COD efficiency up to 89%, which was 81% before, and decrease SVI. Increasing the sludge return ratio proved higher removal efficiency of COD up to 92% in parallel to a significant improvement in both MLVSS and SVI. Both procedures removed filamentous bacteria to the acceptable level. OUR profiles of basin 1 showed a healthy sludge character confirming the efficiency increase.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)910-914
Sayfa sayısı5
DergiFresenius Environmental Bulletin
Hacim11
Basın numarası10 B
Yayın durumuYayınlandı - 1 Eki 2002

Parmak izi

Operational problems in small wastewater treatment plants: A case study' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap