Numerical and experimental comparison of TLA synchronous reluctance motor and induction motor

U. E. Dogru, N. G. Ozcelik, H. Gedik, M. Imeryuz, L. T. Ergene

Araştırma sonucu: Kitap/Rapor/Konferans Bildirisinde BölümKonferans katkısıbilirkişi

7 Atıf (Scopus)

Özet

The paper is focusing the comparison of transverse laminated synchronous reluctance motor (TLA) and squirrel cage induction motor for the same power ratings as 4 kW. The motors are general purpose industrial motors which are having the same stator layout but different rotors. The comparison is made in terms of electrical quantities such as induced voltage, current magnetic quantities such as the air gap flux density and other performance indicators such as torque, efficiency, cost. The finite element analysis and experimental data are used for the comparison.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıProceedings - 2016 IEEE International Power Electronics and Motion Control Conference, PEMC 2016
YayınlayanInstitute of Electrical and Electronics Engineers Inc.
Sayfalar619-624
Sayfa sayısı6
ISBN (Elektronik)9781509017980
DOI'lar
Yayın durumuYayınlandı - 21 Kas 2016
Etkinlik17th IEEE International Power Electronics and Motion Control Conference, PEMC 2016 - Varna, Bulgaria
Süre: 25 Eyl 201628 Eyl 2016

Yayın serisi

AdıProceedings - 2016 IEEE International Power Electronics and Motion Control Conference, PEMC 2016

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???17th IEEE International Power Electronics and Motion Control Conference, PEMC 2016
Ülke/BölgeBulgaria
ŞehirVarna
Periyot25/09/1628/09/16

Bibliyografik not

Publisher Copyright:
© 2016 IEEE.

Parmak izi

Numerical and experimental comparison of TLA synchronous reluctance motor and induction motor' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap