Numerical analysis of the flow in centrifugal pump impeller

Kemal Sarioglu*, Erkan Ayder

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Konferansa katkıYazıbilirkişi

Özet

A flow solver, that allows the evaluation of the effects of different design parameters on the impeller performance, has been developed. Quasi 3D Euler equations, including artificial compressibility approach for incompressible flows, are written in quasi-conservative form and are solved by using a finite volume method that employs Runge-Kutta time stepping. The solution is obtained on the blade to blade stream surface by taking into account the thickness of the meridional stream robe. The solver is used to analyze the flow field inside different pump impellers for which experimental data is available. The comparison of the calculated and measured results reveals that the flow solver is capable of predicting impeller performances. The present paper also shows that the performance test of a centrifugal impeller may be carried out by using a numerical code in a cheaper and less time consuming way.

Orijinal dilİngilizce
Yayın durumuYayınlandı - 1997
EtkinlikProceedings of the 1997 ASME Fluids Engineering Division Summer Meeting, FEDSM'97. Part 16 (of 24) - Vancouver, Can
Süre: 22 Haz 199726 Haz 1997

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???Proceedings of the 1997 ASME Fluids Engineering Division Summer Meeting, FEDSM'97. Part 16 (of 24)
ŞehirVancouver, Can
Periyot22/06/9726/06/97

Parmak izi

Numerical analysis of the flow in centrifugal pump impeller' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap