Özet
A novel method was developed for the determination of calcium, magnesium, potassium, iron, copper, zinc, and manganese and phosphorous in various kinds of breads samples sold in Turkey by microwave plasma-atomic emission spectrometry (MIP-AES). Breads were dried at 100 °C for one day, ground thoroughly and then digested using nitric acid/hydrogen per oxide (3:1). The analytes in certified reference wheat flour and maize flour samples were determined in the uncertainty limits of the certified values as well as the analytes added to the mixture of ground bread and acid mixture prior to digestion were recovered quantitatively (>90%). Therefore, all determinations were made by linear calibration technique using aqueous standards. The LOD values for Ca, Cu, Fe, K, Mg, Mn, P and Zn were 13.1, 0.28, 4.47, 118, 1.10, 0.41, 7550 and 3.00 ng mL-1, respectively. No spectral interference was detected at the working wavelengths of the analytes.
Orijinal dil | İngilizce |
---|---|
Sayfa (başlangıç-bitiş) | 245-248 |
Sayfa sayısı | 4 |
Dergi | Food Chemistry |
Hacim | 200 |
DOI'lar | |
Yayın durumu | Yayınlandı - 1 Haz 2016 |
Bibliyografik not
Publisher Copyright:© 2016 Elsevier Ltd. All rights reserved.
Finansman
We are grateful to Agilent Technologies and SEM, Agilent Authorized Distributor in Turkey for providing MP-AES 4200 spectrometer. Also thanks to Nur Sebahi for her helpful work during this study.
Finansörler | Finansör numarası |
---|---|
Agilent Technologies |