TY - JOUR
T1 - Method development for the determination of cadmium in lipsticks directly by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
AU - Tinas, Hande
AU - Ozbek, Nil
AU - Akman, Suleyman
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/5
Y1 - 2018/5
N2 - A practical and fast method was developed for the determination of cadmium in lipstick by high-resolution continuum source graphite furnace atomic absorption spectrometry with solid sampling. Since digestion step was not applied, the method was fast, simple, cheap and environmentally friendly. In addition, the risks of contamination and/or analyte loss prior to analysis were eliminated. Lipstick samples were put on the platform around 1.0 to 2.5 mg, Pd was injected as a modifier and introduced to the furnace by means of manual solid sampler. Interference-free determination of cadmium was carried out using aqueous standards for calibration applying 850 °C for pyrolysis and 1600 °C for atomization. The aqueous cadmium standard added on a solid lipstick was quantitatively recovered. The limit of detection and characteristic mass were 5.0 pg and 2.8 pg, respectively. Finally, the cadmium concentrations in various kinds of lipsticks were determined applying the optimized conditions developed in this study. Additionally, micro-scale heterogeneity of cadmium distribution in the samples were determined.
AB - A practical and fast method was developed for the determination of cadmium in lipstick by high-resolution continuum source graphite furnace atomic absorption spectrometry with solid sampling. Since digestion step was not applied, the method was fast, simple, cheap and environmentally friendly. In addition, the risks of contamination and/or analyte loss prior to analysis were eliminated. Lipstick samples were put on the platform around 1.0 to 2.5 mg, Pd was injected as a modifier and introduced to the furnace by means of manual solid sampler. Interference-free determination of cadmium was carried out using aqueous standards for calibration applying 850 °C for pyrolysis and 1600 °C for atomization. The aqueous cadmium standard added on a solid lipstick was quantitatively recovered. The limit of detection and characteristic mass were 5.0 pg and 2.8 pg, respectively. Finally, the cadmium concentrations in various kinds of lipsticks were determined applying the optimized conditions developed in this study. Additionally, micro-scale heterogeneity of cadmium distribution in the samples were determined.
KW - Cadmium
KW - High-resolution continuum source graphite furnace atomic absorption spectrometry
KW - Lipstick
KW - Solid sampling
UR - http://www.scopus.com/inward/record.url?scp=85044589144&partnerID=8YFLogxK
U2 - 10.1016/j.microc.2018.01.031
DO - 10.1016/j.microc.2018.01.031
M3 - Article
AN - SCOPUS:85044589144
SN - 0026-265X
VL - 138
SP - 316
EP - 320
JO - Microchemical Journal
JF - Microchemical Journal
ER -