Mechanical properties of CAD/CAM manufactured and prefabricated endodontic posts

Gulden Sinmazisik*, Bilge Tarcin, Turgut Gulmez

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Kitap/Rapor/Konferans Bildirisinde BölümKonferans katkısıbilirkişi

Özet

The aim of this study was to evaluate the stiffness, elastic limit and strength of CAD/CAM manufactured metal and zirconia posts in comparison to prefabricated zirconia and glass-fiber posts. Materials and methods: Four types of posts were investigated in this study (n=40). Prefabricated posts made of zirconia (Cosmopost) and glass-fiber reinforced composite (FRC Postec Plus), and Cr-Co (Magnum Lucens) and zirconia (Zirkonzahn) posts manufactured with a CAD/CAM system were used. Artificial root canals with similar diameters to those of the posts were drilled on a stainless steel metal block and the posts were cemented with a self-etch/self-adhesive dual cure resin cement (Totalcem). The posts were loaded in a universal testing device at an inclination of 135 degrees at a crosshead speed of 1mm/min. The force-deflection curves were recorded, and stiffness, elastic limit and strength of the posts were determined. Data were analyzed statistically using Mann Whitney U and Kruskall Wallis tests. Results: The difference between the strength, elastic limit and also stiffness values of the groups was statistically highly significant (p<0.01). CAD/CAM Cr-Co posts showed the highest values of strength, elastic limit and stiffness amongst all the posts investigated. CAD/CAM zirconia posts had the lowest values of strength, and FRC had the lowest values of elastic limit and stiffness. Cosmopost had higher values of elastic limit and stiffness compared to CAD/CAM zirconia posts. Conclusions: If an endodontic post restoration is required, functional load and aesthetics should be considered in addition to mechanical properties of the material selected.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıBioceramics 23
YayınlayanTrans Tech Publications Ltd
Sayfalar649-654
Sayfa sayısı6
ISBN (Basılı)9783037852552
DOI'lar
Yayın durumuYayınlandı - 2012
Etkinlik23rd Symposium and Annual Meeting of International Society for Ceramics in Medicine, ISCM 2011 - Istanbul, Turkey
Süre: 6 Kas 20119 Kas 2011

Yayın serisi

AdıKey Engineering Materials
Hacim493-494
ISSN (Basılı)1013-9826
ISSN (Elektronik)1662-9795

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???23rd Symposium and Annual Meeting of International Society for Ceramics in Medicine, ISCM 2011
Ülke/BölgeTurkey
ŞehirIstanbul
Periyot6/11/119/11/11

Parmak izi

Mechanical properties of CAD/CAM manufactured and prefabricated endodontic posts' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap