Özet
The effects of membrane fouling reducers (MFRs) (the cationic polyelectrolyte (CPE) and FeCI3) on membrane fouling were studied in a lab-scale jet loop submerged membrane bioreactor (JL-SMBR) system. The optimum dosages of MFRs (CPE dosage=20mgg-1MLSS, FeCI3 dosage=14mgg-1MLSS) were continuously fed to JL-SMBR system. The soluble and bound EPS concentrations as well as MLSS concentration in the mixed liquor of JL-SMBR were not changed substantially by the addition of MFRs. However, significant differences were observed in particle size and relative hydrophobicity. Filtration tests were performed by using different membrane types (polycarbonate (PC) and nitrocellulose mixed ester (ME)) and various pore sizes (0.45-0.22-0.1μm). The steady state fluxes (Jss) of membranes increased at all membranes after MFRs addition to JL-SMBR. The filtration results showed that MFRs addition was an effective approach in terms of improvement in filtration performance for both membrane types.
| Orijinal dil | İngilizce |
|---|---|
| Sayfa (başlangıç-bitiş) | 6843-6849 |
| Sayfa sayısı | 7 |
| Dergi | Bioresource Technology |
| Hacim | 102 |
| Basın numarası | 13 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - Tem 2011 |
| Harici olarak yayınlandı | Evet |
Finansman
This study was financially supported by the TUBITAK, the Scientific and Technological Research Council of Turkey (Project No: 108Y129).
| Finansörler | Finansör numarası |
|---|---|
| TUBITAK | |
| Türkiye Bilimsel ve Teknolojik Araştirma Kurumu | 108Y129 |
Parmak izi
Influence of membrane fouling reducers (MFRs) on filterability of disperse mixed liquor of Jet Loop Bioreactors' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.Alıntı Yap
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver