In-use performance assessment of rendered autoclaved aerated concrete walls by long-term moisture monitoring

Hülya Kus*, Kjell Nygren, Peter Norberg

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: ???type-name???Makalebilirkişi

29 Atıf (Scopus)

Özet

The importance of long-term performance and durability of building materials and components has received increasing consideration with regard to a sustainable built environment. Degradation due to exposure to environment conditions, particularly driving rain, play a significant role in the service life of porous materials used in external wall components. Microenvironment monitoring data are presented in this paper to show how different surface coatings can contribute to moisture performance of external walls made of autoclaved aerated concrete (AAC). Renderings modified with hydrophobic products on AAC substrate prove to have less wetting and better drying properties than unmodified renderings according to the performance assessment based on the amount and duration of moisture measured in the material.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)677-687
Sayfa sayısı11
DergiBuilding and Environment
Hacim39
Basın numarası6
DOI'lar
Yayın durumuYayınlandı - Haz 2004

Parmak izi

In-use performance assessment of rendered autoclaved aerated concrete walls by long-term moisture monitoring' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap