Implementation of maj orization-minimization (MM) algorithm for 3D total variation minimization in DBT image reconstruction

Adem Polat, Nuno Matela, Ana Margarida Mota, Isa Yildirim

Araştırma sonucu: ???type-name???Konferans katkısıbilirkişi

2 Atıf (Scopus)

Özet

Digital Breast Tomosynthesis (DBT) is a developing imaging modality which produces 3D images of a breast. Iterative image reconstruction techniques, such as Algebraic reconstruction technique (ART), have been proposed to help increasing success in detecting masses and micro-calcifications. To enhance the quality of reconstructed image, total variation (TV) minimization was applied to the images reconstructed by ART. Nowadays, the number of published papers dealing with 3D TV minimization on ART (ART+TV3D) tends to increase. On the other hand, in the signal processing literature, a new majorization-minimization (MM) algorithm on TV denoising is described for an N-point x(n) as 1D signal. According to our literature review, this 1D MM algorithm has not been applied to DBT studies yet. In this paper, we propose a method to combine MM1D algorithm with ART+TV3D: "ART+TV3D+MM1D". Both quantitative and qualitative analyses of the proposed method ART+TV3D+MM1D, ART+TV3D, and ART are performed for a phantom that mimics 3D breast and a real 3D breast phantom with 301x236x8-dimensions.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığı2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
YayınlayanInstitute of Electrical and Electronics Engineers Inc.
ISBN (Elektronik)9781509016426
DOI'lar
Yayın durumuYayınlandı - 16 Eki 2017
Etkinlik2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 - Strasbourg, France
Süre: 29 Eki 20166 Kas 2016

Yayın serisi

Adı2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
Hacim2017-January

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
Ülke/BölgeFrance
ŞehirStrasbourg
Periyot29/10/166/11/16

Bibliyografik not

Publisher Copyright:
© 2016 IEEE.

Parmak izi

Implementation of maj orization-minimization (MM) algorithm for 3D total variation minimization in DBT image reconstruction' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap