High-linearity Gilbert-cell mixer design for cryogenic applications

Emre Altuner, Ismail Serdar Özoğuz, Mustafa Berke Yelten*

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: ???type-name???Makalebilirkişi

2 Atıf (Scopus)

Özet

A Gilbert-cell mixer is designed for operation in cryogenic conditions (-196∘C) using UMC 180 nm CMOS technology. The operating frequency is determined as 5 GHz. The proposed mixer achieves an IIP3 of 12.8 dBm, a 1-dB compression of 2.19 dBm, and a conversion gain of around 4 dB at -196∘C. The design performance has been compared with the outcomes acquired at room temperature. It is verified that cryogenic conditions enable higher linearity and lower noise figure that elevates the mixer design performance.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)249-256
Sayfa sayısı8
DergiAnalog Integrated Circuits and Signal Processing
Hacim113
Basın numarası2
DOI'lar
Yayın durumuYayınlandı - Kas 2022

Bibliyografik not

Publisher Copyright:
© 2022, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Finansman

This work was supported by the Technological Research Council of Turkey under the project TÜBİTAK 1001 215E080.

FinansörlerFinansör numarası
Technological Research Council of Turkey1001 215E080

    Parmak izi

    High-linearity Gilbert-cell mixer design for cryogenic applications' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap