Ana gezinime geç Aramaya geç Ana içeriğe geç

Heat removal from oscillating flow in a vertical annular channel

  • Unal Akdag*
  • , Mustafa Ozdemir
  • , A. Feridun Ozguc
  • *Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Dergiye katkıMakalebilirkişi

19 Atıf (Scopus)

Özet

In this study, heat removal from a surface, which is located into the reciprocating flow in a vertical annular liquid column, is investigated experimentally. The experiments are carried out for four different oscillation frequencies and three heat fluxes while the amplitude remains constant for all cases. Instantaneous and time-averaged surface and bulk temperature variations are presented. The cycle-averaged values are considered in the calculation of heat transfer using the experimental measurements. Heat removal from the cold surface due to the oscillating liquid column is determined in terms of Nusselt number. Based on the experimental data, an empirical equation is obtained for the cycle averaged Nusselt number as a function of kinetic Reynolds number.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)393-400
Sayfa sayısı8
DergiHeat and Mass Transfer
Hacim44
Basın numarası4
DOI'lar
Yayın durumuYayınlandı - Şub 2008

Parmak izi

Heat removal from oscillating flow in a vertical annular channel' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap