Ana gezinime geç Aramaya geç Ana içeriğe geç

Experimental stress analysis of elevator guiding equipment

  • Istanbul Technical University

Araştırma çıktısı: Kitap/Rapor/Konferans Bildirisinde BölümBölümHakem

3 Atıf (Scopus)

Özet

Guide rails which take place in structure of elevator, are the important elements for safety of elevator systems. They have attached together end to end with the fishplates and bolts, and are anchored to wall with brackets. Connections between guide rails and brackets are provided by clips. To ensure the safe operation of elevators, the guide rails, fishplates, brackets, bolts, clips have enough strength against to loads and forces which affect these elements. In this study, shear tests are performed to examine mechanical properties of bolts and clips which are used guide rail anchor element. The results which are gained from stress calculations and experiments are compared and interpreted.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıAdvanced Design and Manufacture V
YayınlayanTrans Tech Publications Ltd
Sayfalar177-180
Sayfa sayısı4
Baskı1
ISBN (Basılı)9783037858196
DOI'lar
Yayın durumuYayınlandı - 6 Oca 2014

Yayın serisi

AdıKey Engineering Materials
Sayı1
Hacim572
ISSN (Basılı)1013-9826
ISSN (Elektronik)1662-9795

Parmak izi

Experimental stress analysis of elevator guiding equipment' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap