Özet
This study presents a parametric study on the performance aspects, through exergy analysis, of the multistage hydrogen gas storage subsystem in a hydropower-based-hydrogen gas fueling station producing 3 kg of hydrogen per hour and storing it. In order to perform an exergy analysis, the following parameters are taken into consideration: (i) mass flow rate of hydrogen (3 kg/h), (ii) inlet pressure of hydrogen (ranging from 1 to 200 bar), (iii) hydrogen storage pressure (ranging from 200 to 900 bar), (iv) dead state temperature (at 25 °C), (v) efficiency of electrical motor (90%), (vi) mechanical efficiency (95%), and (vii) polytropic efficiency (90%). It is obtained that increasing inlet pressure of hydrogen gas decreases the energy consumption for compression and storage process while increasing exergy efficiency. Moreover, it is noticed that increasing storage pressure increases the exergy content of hydrogen gas.
Orijinal dil | İngilizce |
---|---|
Sayfa (başlangıç-bitiş) | 11440-11450 |
Sayfa sayısı | 11 |
Dergi | International Journal of Hydrogen Energy |
Hacim | 36 |
Basın numarası | 17 |
DOI'lar | |
Yayın durumu | Yayınlandı - Ağu 2011 |
Harici olarak yayınlandı | Evet |
Finansman
The authors acknowledge the support provided by Niğde University and Rize University in Turkey and the Natural Sciences and Engineering Research Council of Canada.
Finansörler | Finansör numarası |
---|---|
Niğde University | |
Rize University in Turkey | |
Natural Sciences and Engineering Research Council of Canada |