Ana gezinime geç Aramaya geç Ana içeriğe geç

Evaluation of a two-temperature control structure for a two-reactant/two-product type of reactive distillation column

  • Devrim B. Kaymak
  • , William L. Luyben*
  • *Bu çalışma için yazışmadan sorumlu yazar
  • Lehigh University

Araştırma çıktısı: Dergi yayını › Makale › Hakemli

48 Atıf (Scopus)

Özet

Several different control structures have been proposed for reactive distillation columns. The appropriate control structure depends on the flowsheet and on the type of reactions occurring in the column. If two reactants are involved and if it is desirable to operate the process without any excess of reactant, it is necessary to manage the fresh feed streams so that the stoichiometry is exactly balanced. A composition analyzer that measures an internal composition in the column is often required. However, if two products are produced, it is possible to avoid the use of an analyzer by using two temperatures in the column to adjust the two feed streams. This type of structure was proposed by Roat et al. [Roat, S., Downs. J., Vogel, E., Doss, J., 1986. Integration of rigorous dynamic modeling and control system synthesis for distillation columns. In: Chemical Process Control-CPC III. Elsevier, Amsterdam.] for the ideal reaction A + B ↔ C + D in one of the earliest papers dealing with reactive distillation control. The purpose of this paper is to explore the effectiveness of this two-temperature control structure for various column designs (number of reactive stages) to quantify the impact of design on controllability. We also discuss the issues of the selection of the trays whose temperatures are to be controlled and the tuning of the two interacting temperature controllers. Disturbances in production rate and fresh feed compositions are made to examine the rangeability of this control structure. Both an ideal reaction system and the methyl acetate system are studied. One of the main conclusions is that the locations of the temperature control trays should be made such that the two temperature controllers both have direct action (an increase in temperature increases feed), which requires negative openloop process gains for both loops.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)4432-4450
Sayfa sayısı19
DergiChemical Engineering Science
Hacim61
Basın numarası13
DOI'lar
Yayın durumuYayınlandı - Tem 2006
Harici olarak yayınlandıEvet

Parmak izi

Evaluation of a two-temperature control structure for a two-reactant/two-product type of reactive distillation column' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap