Entropy generation through hexagonal cross-sectional duct for constant wall temperature in laminar flow

  • Hakan F. Öztop*
  • , Ahmet Z. Sa̧hin
  • , Ihsan Daǧtekin
  • *Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Dergiye katkıMakalebilirkişi

21 Atıf (Scopus)

Özet

Second law analysis of heat transfer in laminar flow for hexagonal cross-section duct was analysed analytically. Geometrical effect of hexagonal duct was considered. The variation of total entropy generation was studied along the duct length. As a working fluid water and unused engine oil were used to compare the effect of fluid in the duct. Results were compared with circular cross-section duct. It is found that the non-dimensional entropy generation in a hexagonal cross-section duct can be as high as a factor of four than that for a circular duct. Further, the unused engine oil gives up to about ten times lower non-dimensional entropy generation values than that of water but needs about ten times more pumping power to heat transfer ratio.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)725-737
Sayfa sayısı13
DergiInternational Journal of Energy Research
Hacim28
Basın numarası8
DOI'lar
Yayın durumuYayınlandı - 25 Haz 2004
Harici olarak yayınlandıEvet