Ana gezinime geç Aramaya geç Ana içeriğe geç

Effect of sludge management strategies on minimizing global warming potential at a municipal wastewater treatment plant of a metropolitan city

  • Cigdem Yangin Gomec*
  • , Huseyin Guven
  • , Ozgur Ozdemir
  • , Izzet Ozturk
  • *Bu çalışma için yazışmadan sorumlu yazar
  • Istanbul Technical University
  • Kayseri Water and Sewerage Administration

Araştırma çıktısı: Dergi yayını › Makale › Hakemli

Özet

In this paper, improvement in biogas production and its total energy equivalence were evaluated in the case of kitchen waste (KW) integration, and results were compared with the current situation (without KW integration) at a municipal wastewater treatment plant (WWTP) located in one of the metropolitan cities in Turkey. Moreover, the effect of different sludge disposal alternatives (e.g. co-combustion, composting, etc.) was discussed from the aspects including energy consumption/ production and the greenhouse gases (GHGs) emission, while comparing the results with the current sludge disposal via uncontrolled landfilling. In the current situation, about 18% of the annual electricity requirement of the WWTP could be provided from the produced biogas by mesophilic digestion, whereas more than half of the annual electricity requirement could be provided with KW integration when the operational temperature of the anaerobic digestion is shifted to thermophilic condition. At the same time, all heat requirements could be supplied with the produced biogas for each case. Moreover, substantial excess heat (i.e. 3 times more in the case of thermophilic digestion and KW integration) is obtained which can be utilized elsewhere in the premises of the WWTP. When global warming potential (GWP) of the WWTP is evaluated in terms of current sludge disposal method; results indicated ca. 416, 604 and 509 kg CO 2 -eq/person/year emission factors without and with KW integration at mesophilic and with KW integration at thermophilic digestion, respectively. Moreover, in terms of composting (for both land use and peat substitution) and co-combustion alternatives for each option, minimum GWP is found when sludge is disposed of via co-combustion after mesophilic digestion with ca. -267 kg CO 2 -eq/person/year. Hence, the WWTPs should be operated and/or upgraded regarding not only energy saving but also GHGs emission decrease that is worldwide concern from the point of global warming.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)3153-3160
Sayfa sayısı8
DergiFresenius Environmental Bulletin
Hacim23
Basın numarası12
Yayın durumuYayınlandı - 2014

Bibliyografik not

Publisher Copyright:
© 2014 Parlar Scientific Publications. All rights reserved.

BM SKH

Bu sonuç, aşağıdaki Sürdürülebilir Kalkınma Hedefine/Hedeflerine katkıda bulunur

  1. SKH 6 - Temiz Su ve Sanitasyon
    SKH 6 Temiz Su ve Sanitasyon
  2. SKH 7 - Erişilebilir ve Temiz Enerji
    SKH 7 Erişilebilir ve Temiz Enerji
  3. SKH 11 - Sürdürülebilir Şehirler ve Topluluklar
    SKH 11 Sürdürülebilir Şehirler ve Topluluklar
  4. SKH 12 - Sorumlu Üretim ve Tüketim
    SKH 12 Sorumlu Üretim ve Tüketim
  5. SKH 13 - İklim Eylemi
    SKH 13 İklim Eylemi

Parmak izi

Effect of sludge management strategies on minimizing global warming potential at a municipal wastewater treatment plant of a metropolitan city' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap