Özet
Electrochemical reduction and determination of montelukast (MKS) was studied in methanol - 0.1M HCl solution (1:1, v/v) by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at chitosan modified carbon paste electrode. The linear range was 1.70×10-7-1.83×10-5M for DPV analysis. Limit of detection (LOD) and limit of quantification (LOQ) were 5.32×10-8M and 1.61×10-7M, respectively. The developed method was successfully applied to the determination of MKS in tablets and spiked human plasma. The results obtained were in good agreement with those obtained using a reported spectrofluorimetric technique.
Orijinal dil | İngilizce |
---|---|
Sayfa (başlangıç-bitiş) | 1796-1802 |
Sayfa sayısı | 7 |
Dergi | Electroanalysis |
Hacim | 25 |
Basın numarası | 7 |
DOI'lar | |
Yayın durumu | Yayınlandı - Tem 2013 |