Ana gezinime geç Aramaya geç Ana içeriğe geç

Detection and Restoration Pipeline for Phase Contrast Microscopy Time Series Images

  • Mahmut Uçar
  • , Leonardo O. Iheme
  • , Sevgi Önal
  • , Özden Y. Özuysal
  • , Devrim P. Okvur
  • , Behçet U. Töreyin
  • , Devrim Ünay
  • Izmir Democracy University
  • ARI1 Teknokent
  • Izmir Institute of Technology
  • Istanbul Technical University

Araştırma sonucu: Kitap/Rapor/Konferans Bildirisinde BölümKonferans katkısıbilirkişi

Özet

We propose a pre-processing pipeline for the de-tection and restoration of distorted frames in phase-contrast microscopy time-series images. The analysis is based on the average intensity values of the frames within any given time- series image. The extent of the correction of intensity variation in frames is determined by the normalization of the difference between the current frame's average intensity and the median of average intensity of all frames. Our restoration algorithm preserves regional trans-passing pixels, does not cause new distortions, and increases the histogram similarity between the distorted and non-distorted frames. The algorithm was validated on 15,395 time-series image frames from 27 experiments and the results were found to be visually and quantitatively accurate.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıTIPTEKNO 2022 - Medical Technologies Congress, Proceedings
YayınlayanInstitute of Electrical and Electronics Engineers Inc.
ISBN (Elektronik)9781665454322
DOI'lar
Yayın durumuYayınlandı - 2022
Etkinlik2022 Medical Technologies Congress, TIPTEKNO 2022 - Antalya, Türkiye
Süre: 31 Eki 20222 Kas 2022

Yayın serisi

AdıTIPTEKNO 2022 - Medical Technologies Congress, Proceedings

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???2022 Medical Technologies Congress, TIPTEKNO 2022
Ülke/BölgeTürkiye
ŞehirAntalya
Periyot31/10/222/11/22

Bibliyografik not

Publisher Copyright:
© 2022 IEEE.

Finansman

This work is supported by the Scientific and Technological Research Council of Turkey (TUBITAK) under grant no 119E578. The data used in this study is collected under the Marie Curie IRG grant (no: FP7 PIRG08-GA-2010-27697). 978-1-6654-5432-2/22/$31.00 ©2022 IEEE

FinansörlerFinansör numarası
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu119E578, FP7 PIRG08-GA-2010-27697, 978-1-6654-5432-2/22

    Parmak izi

    Detection and Restoration Pipeline for Phase Contrast Microscopy Time Series Images' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

    Alıntı Yap