Özet
In this paper, the hydrophobicity performance of acommercially available silicone-rubber samples was investigated by using the corona discharge-degradation test and dynamic drop test (DDT). The tests were carried out under AC, +DC, and -DC voltages. In the corona discharge-degradation test, corona discharge was applied to two samples under certain temperatures and humidity for 2 hours, and their hydrophobicity losses were examined using contact angle measurements. Then, the recovery of their hydrophobicity property was investigated. In the dynamic drop test, the loss of hydrophobicity with respect to time and the formation of a water path on the sample surface were observed. Five identical samples were utilized for the DDT.
| Orijinal dil | İngilizce |
|---|---|
| Ana bilgisayar yayını başlığı | 2022 IEEE International Conference on High Voltage Engineering and Applications, ICHVE 2022 |
| Yayınlayan | Institute of Electrical and Electronics Engineers Inc. |
| ISBN (Elektronik) | 9781665407502 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - 2022 |
| Etkinlik | 2022 IEEE International Conference on High Voltage Engineering and Applications, ICHVE 2022 - Chongqing, China Süre: 25 Eyl 2022 → 29 Eyl 2022 |
Yayın serisi
| Adı | 2022 IEEE International Conference on High Voltage Engineering and Applications, ICHVE 2022 |
|---|
???event.eventtypes.event.conference???
| ???event.eventtypes.event.conference??? | 2022 IEEE International Conference on High Voltage Engineering and Applications, ICHVE 2022 |
|---|---|
| Ülke/Bölge | China |
| Şehir | Chongqing |
| Periyot | 25/09/22 → 29/09/22 |
Bibliyografik not
Publisher Copyright:© 2022 IEEE.