TY - JOUR
T1 - Comparison of the energy performance between flat-plate and heat pipe evacuated tube collectors for solar water heating systems under mediterranean climate conditions
AU - Maraj, Altin
AU - Londo, Andonaq
AU - Firat, Coskun
AU - Gebremedhin, Alemayehu
N1 - Publisher Copyright:
© 2019, International Centre for Sustainable Development of Energy, Water and Environment Systems SDEWES. All rights reserved.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - In this paper, the energy performance of a flat-plate collector and a heat pipe evacuated tube collector exploited for domestic hot water production in the Mediterranean climate is compared. For this purpose, yearly data obtained from two field-trial solar water heating systems are used. The selected systems are with forced circulation and installed near each other. The studied solar collectors are installed on the roof with the same slope angle of 45° and the surface azimuthal angle of 10°. The installed surface area of the flat-plate solar collector is 4.41 m 2 , whereas for the heat pipe evacuated tube collector is 1.5 m 2 . The annual irradiation on solar collector plane was 1,456 kWh/m 2 year. Obtained results showed that the annual solar yield for the flat-plate collector was 664 kWh/m 2 year, whereas for the heat pipe evacuated tube collector was 885 kWh/m 2 year. The annual average collector efficiencies were 0.494 and 0.62, respectively.
AB - In this paper, the energy performance of a flat-plate collector and a heat pipe evacuated tube collector exploited for domestic hot water production in the Mediterranean climate is compared. For this purpose, yearly data obtained from two field-trial solar water heating systems are used. The selected systems are with forced circulation and installed near each other. The studied solar collectors are installed on the roof with the same slope angle of 45° and the surface azimuthal angle of 10°. The installed surface area of the flat-plate solar collector is 4.41 m 2 , whereas for the heat pipe evacuated tube collector is 1.5 m 2 . The annual irradiation on solar collector plane was 1,456 kWh/m 2 year. Obtained results showed that the annual solar yield for the flat-plate collector was 664 kWh/m 2 year, whereas for the heat pipe evacuated tube collector was 885 kWh/m 2 year. The annual average collector efficiencies were 0.494 and 0.62, respectively.
KW - Collector efficiency
KW - Evacuated tube collector
KW - Flat-plate collector
KW - Heat pipe
KW - Losses
KW - Useful energy gain
UR - http://www.scopus.com/inward/record.url?scp=85061301520&partnerID=8YFLogxK
U2 - 10.13044/j.sdewes.d6.0228
DO - 10.13044/j.sdewes.d6.0228
M3 - Article
AN - SCOPUS:85061301520
SN - 1848-9257
VL - 7
SP - 87
EP - 100
JO - Journal of Sustainable Development of Energy, Water and Environment Systems
JF - Journal of Sustainable Development of Energy, Water and Environment Systems
IS - 1
ER -