Comparison of the energy performance between flat-plate and heat pipe evacuated tube collectors for solar water heating systems under mediterranean climate conditions

Altin Maraj*, Andonaq Londo, Coskun Firat, Alemayehu Gebremedhin

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Dergiye katkıMakalebilirkişi

13 Atıf (Scopus)

Özet

In this paper, the energy performance of a flat-plate collector and a heat pipe evacuated tube collector exploited for domestic hot water production in the Mediterranean climate is compared. For this purpose, yearly data obtained from two field-trial solar water heating systems are used. The selected systems are with forced circulation and installed near each other. The studied solar collectors are installed on the roof with the same slope angle of 45° and the surface azimuthal angle of 10°. The installed surface area of the flat-plate solar collector is 4.41 m 2 , whereas for the heat pipe evacuated tube collector is 1.5 m 2 . The annual irradiation on solar collector plane was 1,456 kWh/m 2 year. Obtained results showed that the annual solar yield for the flat-plate collector was 664 kWh/m 2 year, whereas for the heat pipe evacuated tube collector was 885 kWh/m 2 year. The annual average collector efficiencies were 0.494 and 0.62, respectively.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)87-100
Sayfa sayısı14
DergiJournal of Sustainable Development of Energy, Water and Environment Systems
Hacim7
Basın numarası1
DOI'lar
Yayın durumuYayınlandı - 1 Mar 2019

Bibliyografik not

Publisher Copyright:
© 2019, International Centre for Sustainable Development of Energy, Water and Environment Systems SDEWES. All rights reserved.

Parmak izi

Comparison of the energy performance between flat-plate and heat pipe evacuated tube collectors for solar water heating systems under mediterranean climate conditions' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap