Özet
Railway electrification systems are designed with regard to the operating data and design parameters. The minimum voltage rating required by traction during the operation should be provided. The maximum voltage drop on a line determines the minimum traction voltage. This voltage should be maintened within certain limits for the continuity of operation. In this study, the maximum voltage drop generated via traction was determined using artificial neural network (ANN) and adaptive neuro-fuzzy inference system (ANFIS) for a 25-kV AC-supplied railway. The voltage drop on line was calculated with regard to the operating data using ANN and ANFIS. ANN and ANFIS were explained, and the results were compared. The Levenberg-Marquardt (LM) algorithm was used for the ANN model. The LM algorithm is preferred because of the speed and stability it provides for the training of ANNs. The data created for one-way supply status were examined for simulation.
Orijinal dil | İngilizce |
---|---|
Sayfa (başlangıç-bitiş) | 26-35 |
Sayfa sayısı | 10 |
Dergi | Istanbul University - Journal of Electrical and Electronics Engineering |
Hacim | 18 |
Basın numarası | 1 |
DOI'lar | |
Yayın durumu | Yayınlandı - 2018 |
Harici olarak yayınlandı | Evet |
Bibliyografik not
Publisher Copyright:© Copyright 2018 by Electrica.