Ana gezinime geç Aramaya geç Ana içeriğe geç

Breakdown characteristics of N2 containing 0.125% of SF6

  • Emel Onal*
  • , Ozcan Kalenderli
  • , Kevork Mardikyan
  • *Bu çalışma için yazışmadan sorumlu yazar
  • Istanbul Technical University

Araştırma sonucu: Kitap/Rapor/Konferans Bildirisinde BölümKonferans katkısıbilirkişi

Özet

AC breakdown strengths of N2, SF6 and a mixture of N2+SF6 containing 0.125% of SF6 in nonuniform field were experimentally studied. The electrode gap spacing and the relative gas pressure were varied within the range of 5-25 mm and of 100-500 kPa respectively. The experimental results have shown that the addition of SF6 to N2 causes a significant increase the AC breakdown voltage with respect to N2. Even at about pressures of 250 kPa and 25 mm gap spacing breakdown voltage of mixture were obtained 74% higher than that of pure N2. But at above 400 kPa and 25 mm gap spacing the breakdown voltage 10% is lower than that of pure N2.

Orijinal dilİngilizce
Ana bilgisayar yayını başlığıIEE Conference Publication
YayınlayanIEE
Sayfalar3.305.P3-3.308.P3
Baskı467
ISBN (Basılı)0852967195
Yayın durumuYayınlandı - 1999
EtkinlikProceedings of the 1999 11th International Symposium on 'High Voltage Engineering' (ish99) - London, UK
Süre: 23 Ağu 199927 Ağu 1999

Yayın serisi

AdıIEE Conference Publication
Sayı467
Hacim3
ISSN (Basılı)0537-9989

???event.eventtypes.event.conference???

???event.eventtypes.event.conference???Proceedings of the 1999 11th International Symposium on 'High Voltage Engineering' (ish99)
ŞehirLondon, UK
Periyot23/08/9927/08/99

Parmak izi