Ana gezinime geç Aramaya geç Ana içeriğe geç

Application of surface molecular imprinted magnetic graphene oxide and high performance mimetic behavior of bi-metal ZnCo MOF for determination of atropine in human serum

  • Nafiseh Bagheri
  • , Biuck Habibi*
  • , Alireza Khataee
  • , Javad Hassanzadeh
  • *Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: Dergiye katkıMakalebilirkişi

79 Atıf (Scopus)

Özet

Herein, high performance peroxidase-like activity of zinc and cobalt bi-metal metal-organic framework (ZnCo MOF) is reported and applied for the sensitive measurement of atropine. ZnCo MOF was synthesized by the reaction of 2-methylimidazole with Zn and Co (II) cations in aqueous media. The colorimetric and fluorometric experiments were applied to investigate the catalytic activity of obtained MOF, using o-phenylenediamine (OPD) and terephthalic acid (TA) peroxidase substrates, respectively. The results demonstrated the more efficient mimetic behavior of ZnCo MOF compared with common Zn or Co MOFs. Besides, it was found that atropine hindered the catalytic action of ZnCo MOF and this effect was intensified by increasing the atropine concentration. So, it was considered to design a sensitive analytical assay for atropine detection. To assure a high specific recognition, molecularly imprinted polymer (MIP)-based extraction using magnetic graphene oxide supports was applied to extract atropine before its determination. The combination between the high specific extraction and great catalytic activity of ZnCo MOF led to the ultrasensitive and reliable determination of atropine. The best linear range of calibration graph was achieved using fluorometric detection system for 0.1–45 ng mL−1 atropine concentrations, and detection limit (3Sb/m) was 27 pg mL−1. The relative standard deviations (RSD %) for the determination of 1, and 10 ng mL−1 atropine (n = 5) were 2.13% and 3.08%, respectively. The explained fluorometric assay was examined for the measurement of atropine in biological fluids (Recoveries were in the range of 95.90–103.57%), and the results were validated by an official method.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)286-294
Sayfa sayısı9
DergiTalanta
Hacim201
DOI'lar
Yayın durumuYayınlandı - 15 Ağu 2019
Harici olarak yayınlandıEvet

Bibliyografik not

Publisher Copyright:
© 2019 Elsevier B.V.

Parmak izi

Application of surface molecular imprinted magnetic graphene oxide and high performance mimetic behavior of bi-metal ZnCo MOF for determination of atropine in human serum' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.

Alıntı Yap