Analysis of reinforced concrete beams with corrosion damaged stirrups for shear capacity

Christopher Higgins, William C. Farrow, O. Tugrul Turan

Araştırma sonucu: ???type-name???Makalebilirkişi

35 Atıf (Scopus)

Özet

Corrosion of embedded carbon steel is a leading factor in deterioration of ageing conventional reinforced concrete structures. Methods to accurately predict remaining capacity of corrosion damaged elements, especially shear capacity, are lacking. In this paper, ACI-AASHTO approach, strut and tie method, modified compression field theory, and Response 2000™ were used to predict the shear strength of corrosion damaged and undamaged test beams. The methods were modified to account for the corrosion induced damage to both the concrete section and stirrups. Each of the methods considered, with the proposed modifications, reasonably estimated the remaining shear capacity of large-size laboratory specimens subjected to accelerated corrosion of embedded stirrups.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)1080-1092
Sayfa sayısı13
DergiStructure and Infrastructure Engineering
Hacim8
Basın numarası11
DOI'lar
Yayın durumuYayınlandı - Kas 2012
Harici olarak yayınlandıEvet

Parmak izi

Analysis of reinforced concrete beams with corrosion damaged stirrups for shear capacity' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.