An ISM-band direct down-conversion double-balanced mixer for biomedical applications

Ercem Yeşil, Onur Ferhanoğlu, Mustafa Berke Yelten*

*Bu çalışma için yazışmadan sorumlu yazar

Araştırma sonucu: ???type-name???Makalebilirkişi

2 Atıf (Scopus)

Özet

In this study, the design of a direct down-conversion, double-balanced Gilbert Mixer at 432 MHz is presented. The proposed circuit achieves a 13.4 dB double-sideband noise figure with an associated flicker corner frequency of 250 kHz. The conversion gain of the mixer is approximately 10.2 dB, with an IIP3 of 8.2 dBm simulated in the post-layout setup at a 1 MHz intermediate frequency. The design of the mixer has been accomplished using the UMC 180 nm CMOS process, and its layout occupies an area of 0.0135 mm2. At the supply voltage of 1.8 V, the mixer consumes approximately 5.15 mW of power.

Orijinal dilİngilizce
Sayfa (başlangıç-bitiş)231-239
Sayfa sayısı9
DergiAnalog Integrated Circuits and Signal Processing
Hacim113
Basın numarası2
DOI'lar
Yayın durumuYayınlandı - Kas 2022

Bibliyografik not

Publisher Copyright:
© 2022, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Finansman

This work was supported by the Technological Research Council of Turkey under the project TÜBİTAK 1001 119E224.

FinansörlerFinansör numarası
Technological Research Council of Turkey1001 119E224