Özet
This paper presents some experimental results of an extensive research on a novel oscillating heat pipe. The heat pipe is formed of three interconnected columns as different from the pulsating heat pipe designs. The dimensions of the heat pipe considered in this study are large enough to neglect the effect of capillary forces. Thus, the self-oscillation of the system is driven by the gravitational force and the phase lag between the evaporation and condensation processes. The overall heat transfer coefficient is found to be approximately constant irrespective of heat load for the experimental cases considered. The results are also compared with the previously published data by other investigators for water as the working fluid and for the same heat input range. The experimental data for the time variation of the liquid column heights and the vapor pressure are correlated algebraically, convenient for practical uses.
| Orijinal dil | İngilizce |
|---|---|
| Sayfa (başlangıç-bitiş) | 527-534 |
| Sayfa sayısı | 8 |
| Dergi | Heat and Mass Transfer |
| Hacim | 43 |
| Basın numarası | 6 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - Nis 2007 |
Parmak izi
An experimental study on an oscillating loop heat pipe consisting of three interconnected columns' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.Alıntı Yap
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver