Özet
The new approach for the determination of sulphur in foods was developed, and the sulphur concentrations of various fresh and dried food samples determined using a high-resolution continuum source flame atomic absorption spectrometer with an air/acetylene flame. The proposed method was optimised and the validated using standard reference materials, and certified values were found to be within the 95% confidence interval. The sulphur content of foods ranged from less than the LOD to 1.5 mg g-1. The method is accurate, fast, simple and sensitive.
| Orijinal dil | İngilizce |
|---|---|
| Sayfa (başlangıç-bitiş) | 460-463 |
| Sayfa sayısı | 4 |
| Dergi | Food Chemistry |
| Hacim | 168 |
| DOI'lar | |
| Yayın durumu | Yayınlandı - 1 Şub 2015 |
Parmak izi
A new approach for the determination of sulphur in food samples by high-resolution continuum source flame atomic absorption spectrometer' araştırma başlıklarına git. Birlikte benzersiz bir parmak izi oluştururlar.Alıntı Yap