The influence of suture material on the strength of horizontal mattress suture configuration for meniscus repair

Onur Hapa*, Ertuǧrul Akşahin, Mehmet Erduran, Serkan Davul, Hasan Havitçioǧlu, Robert F. LaPrade, Ergun Bozdaǧ, Emin Sünbüloǧlu

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

Purpose: Comparison of the mechanical characteristics of meniscal repair fixation using horizontal sutures and six different sutures under submaximal cyclic and load to failure test conditions may aid physicians in selecting a suture type. Methods: A 2-cm long anteroposterior vertical longitudinal incision was created in six groups of bovine medial menisci. Lesions were repaired using a No. 2 suture either composed of polyester or polyester and ultra high-molecular weight polyethylene (UHMWPE), or UHMWPE and polydioxanone or pure UHMWPE. Endpoints included ultimate failure load (N), pull-out stiffness (N/mm), pull-out displacement (mm), cyclic displacement (mm) after 100. cycles, after 500. cycles, and mode of failure. Results: Polyester suture had lower ultimate load than all groups except the suture composed of polyester and UHMWPE (P< .05). Pure UHMWPE suture had higher ultimate failure load than sutures composed of either polyester or polyester plus UHMWPE (P< .05).Predominant failure mode was suture cutting through the meniscus for the groups except for polyester suture which failed by suture rupture. Conclusion: Under cyclic loading conditions in bovine meniscus, braided polyester suture fixation provided lower initial fixation strength than fixation with various high strength sutures composed of pure UHMWPE or a combination of absorbable monofilament polydioxanone and UHMWPE, except for combination of polyester and UHMWPE sutures. Clinical relevance: Present study does not support the usage of the braided polyester sutures instead of high strength sutures composed either partially or totally of ultra-high molecular weight polyethylene for the horizontal suture configuration of meniscus repair.

Original languageEnglish
Pages (from-to)577-580
Number of pages4
JournalKnee
Volume20
Issue number6
DOIs
Publication statusPublished - Dec 2013

Keywords

  • Meniscal repair
  • Meniscus
  • Suture
  • Tensile load

Fingerprint

Dive into the research topics of 'The influence of suture material on the strength of horizontal mattress suture configuration for meniscus repair'. Together they form a unique fingerprint.

Cite this