T1 - Tendon-grasping strength of various suture configurations for rotator cuff repair
AU - Hapa, Onur
AU - Barber, F. Alan
AU - Sünbüloǧlu, Emin
AU - Kocabey, Yavuz
AU - Sarkalkan, N.
AU - Baysal, Gökhan
PY - 2011/10
Y1 - 2011/10
N2 - Purpose: The purpose of the present study is to evaluate the mechanical performance and initial strength of the arthroscopic Mason-Allen, double mattress, inclined Mason-Allen, and lasso loop stitch configurations. Methods: Using 36 sheep infraspinatus tendons, tendon widths and thicknesses were measured with a digital caliper to confirm standardization of the tendons. Four different stitch configurations (Mason-Allen, inclined Mason-Allen, double mattress, and lasso loop) were biomechanically tested with cyclic loading followed by load to failure testing. The cyclic elongation, peak-to-peak displacement, ultimate tensile strength, stiffness, and mode of failure were recorded. Results: Mean tendon widths and thicknesses were statistically the same. The lasso loop (0.7 ± 0.1 mm) demonstrated a mean cyclic elongation greater than the Mason-Allen (0.5 ± 0.3 mm) and double mattress (0.5 ± 0.3 mm) groups (P = 0.011; P = 0.013). No differences were found in ultimate failure load, stiffness, and peak-to-peak displacement for the Mason-Allen (mean 99 ± 42 N, 39 ± 9 N/mm, 0.6 ± 0,1 mm), inclined Mason-Allen (113 ± 52 N, 44 ± 14 N/mm, 0.5 ± 0.1 mm), double mattress stitch (119 ± 68 N, 45 ± 10 N/mm, 0.5 ± 0.1 mm), or lasso loop (100 ± 38 N, 42 ± 7 N/mm, 0.5 ± 0.1 mm) groups (n.s.). Each specimen failed at the suture-tendon interface. Three specimens (two Mason-Allen and one inclined Mason-Allen) failed during cyclic testing. Conclusion: Conventional Mason-Allen configuration can be applied with double-loaded suture anchor safely. Recent modifications of the configurations offer no biomechanical advantage.
AB - Purpose: The purpose of the present study is to evaluate the mechanical performance and initial strength of the arthroscopic Mason-Allen, double mattress, inclined Mason-Allen, and lasso loop stitch configurations. Methods: Using 36 sheep infraspinatus tendons, tendon widths and thicknesses were measured with a digital caliper to confirm standardization of the tendons. Four different stitch configurations (Mason-Allen, inclined Mason-Allen, double mattress, and lasso loop) were biomechanically tested with cyclic loading followed by load to failure testing. The cyclic elongation, peak-to-peak displacement, ultimate tensile strength, stiffness, and mode of failure were recorded. Results: Mean tendon widths and thicknesses were statistically the same. The lasso loop (0.7 ± 0.1 mm) demonstrated a mean cyclic elongation greater than the Mason-Allen (0.5 ± 0.3 mm) and double mattress (0.5 ± 0.3 mm) groups (P = 0.011; P = 0.013). No differences were found in ultimate failure load, stiffness, and peak-to-peak displacement for the Mason-Allen (mean 99 ± 42 N, 39 ± 9 N/mm, 0.6 ± 0,1 mm), inclined Mason-Allen (113 ± 52 N, 44 ± 14 N/mm, 0.5 ± 0.1 mm), double mattress stitch (119 ± 68 N, 45 ± 10 N/mm, 0.5 ± 0.1 mm), or lasso loop (100 ± 38 N, 42 ± 7 N/mm, 0.5 ± 0.1 mm) groups (n.s.). Each specimen failed at the suture-tendon interface. Three specimens (two Mason-Allen and one inclined Mason-Allen) failed during cyclic testing. Conclusion: Conventional Mason-Allen configuration can be applied with double-loaded suture anchor safely. Recent modifications of the configurations offer no biomechanical advantage.
KW - Double mattress stitch
KW - Lasso loop
KW - Mason-Allen
KW - Rotator cuff repair
UR - http://www.scopus.com/inward/record.url?scp=80052870740&partnerID=8YFLogxK
U2 - 10.1007/s00167-010-1322-y
DO - 10.1007/s00167-010-1322-y
M3 - Article
AN - SCOPUS:80052870740
SN - 0942-2056
VL - 19
SP - 1749
EP - 1754
JO - Knee Surgery, Sports Traumatology, Arthroscopy
JF - Knee Surgery, Sports Traumatology, Arthroscopy
IS - 10
ER -