Abstract
A simplified procedure for determining approximate values for the buckling loads of three-dimensional framed structures is developed. The procedure utilises lateral load analysis of structures and yields errors less than 10%, which may be considered suitable for design purposes. The structures with or without rigid floor diaphragms may be considered readily. Buckling loads of both regular and irregular structures may be obtained. The proposed procedure is applied to several numerical examples and it is shown that all the errors are in the acceptable range and generally on the safe side. Determining the buckling loads of structures using SAP2000 is also discussed.
Original language | English |
---|---|
Pages (from-to) | 2344-2352 |
Number of pages | 9 |
Journal | Engineering Structures |
Volume | 29 |
Issue number | 9 |
DOIs | |
Publication status | Published - Sept 2007 |
Keywords
- Buckling load
- Buckling modes
- Irregular structures
- Isolated subassembly
- Rigid floor diaphragms
- SAP2000 applications