TY - JOUR
T1 - Seismic Retrofit of Substandard RC Columns Using Sprayed Glass Fiber-Reinforced Mortar and Basalt Textile Reinforcement
AU - Ates, Ali Osman
AU - Hajihosseinlou, Saeid
AU - Nasrinpour, Amin
AU - Demir, Cem
AU - Comert, Mustafa
AU - Marasli, Muhammed
AU - Ilki, Alper
N1 - Publisher Copyright:
© 2023 Taylor & Francis Group, LLC.
PY - 2024
Y1 - 2024
N2 - This study investigates the seismic retrofit of substandard reinforced concrete (RC) columns through external jacketing of potential plastic hinge zones using sprayed glass fiber-reinforced mortar and basalt textile reinforcement. An innovative spraying method was used to apply the matrix material to the concrete surface. A total number of eight full-scale columns (four reference, four retrofitted) were tested under constant high axial load to capacity ratio and reversed cyclic lateral loading. Columns were constructed using low-strength concrete and transverse reinforcement with various spacing and inadequate hook detailing to mimic the columns in substandard structures. Test results are evaluated in terms of lateral load-drift ratio relationships, displacement ductility, stiffness degradation, energy dissipation, and residual displacements. Evaluation of the test results showed that the proposed technique is effective for seismic retrofit of substandard RC columns, particularly in terms of enhancement of displacement ductility, energy dissipation capacities, and reduction of residual displacements.
AB - This study investigates the seismic retrofit of substandard reinforced concrete (RC) columns through external jacketing of potential plastic hinge zones using sprayed glass fiber-reinforced mortar and basalt textile reinforcement. An innovative spraying method was used to apply the matrix material to the concrete surface. A total number of eight full-scale columns (four reference, four retrofitted) were tested under constant high axial load to capacity ratio and reversed cyclic lateral loading. Columns were constructed using low-strength concrete and transverse reinforcement with various spacing and inadequate hook detailing to mimic the columns in substandard structures. Test results are evaluated in terms of lateral load-drift ratio relationships, displacement ductility, stiffness degradation, energy dissipation, and residual displacements. Evaluation of the test results showed that the proposed technique is effective for seismic retrofit of substandard RC columns, particularly in terms of enhancement of displacement ductility, energy dissipation capacities, and reduction of residual displacements.
KW - Seismic retrofit
KW - TRM
KW - cement-based composites
KW - external jacketing
KW - substandard columns
UR - http://www.scopus.com/inward/record.url?scp=85168862385&partnerID=8YFLogxK
U2 - 10.1080/13632469.2023.2247491
DO - 10.1080/13632469.2023.2247491
M3 - Article
AN - SCOPUS:85168862385
SN - 1363-2469
VL - 28
SP - 1615
EP - 1642
JO - Journal of Earthquake Engineering
JF - Journal of Earthquake Engineering
IS - 6
ER -