Abstract
In the last decades, lessons learnt from the major earthquakes, that occurred in many countries, brought revisions in prevailing seismic design codes. As a consequence of this phenomenon, the current building stock in Turkey is mainly comprised of reinforced concrete (RC) buildings which were designed according to different seismic design codes. The presented paper is a component of a comprehensive investigation which containing three variables i) high axial load ratio defined as axial load divided by the axial capacity, ii) high shear demand defined as the ratio of shear demand at flexural yielding to shear resistance and iii) low transverse reinforcement ratio owing to large spacing among steel reinforcements. Thus, a total of four full-scale square RC columns comprised of i) one column designed to comply with the former Turkish Seismic Design Code (TSDC, 1975) and ii) three columns which are not compliant to any design codes (referred as sub-standard), were tested under high axial load ratio, 0.4 for code-conforming and 0.75 for sub-standard columns, combined with reversed cyclic lateral loading. The columns were also designed to have high shear demand in the order of 0.62 and 0.80 for bare sub-standard according to ACI 318 (2019) and TBEC (2018) design codes as sometimes observed in existing sub-standard structures. In addition to that, the ratio of shear demand for the code-conforming column is calculated 0.43 and 0.50 as per design codes, respectively. Besides, the ratio of transverse reinforcement area to the minimum required transverse reinforcement area was 0.19 and 0.77 for sub-standard columns according to ACI 318 (2019) and TBEC (2018), respectively. For the code-conforming column, the aforementioned ratio was 0.57 and 1.32 for both design codes, in the same manner. One of the sub-standard columns was kept as a reference column while the other two of them have been externally jacketed with one layer or two layers of carbon fiber-reinforced polymer (CFRP) sheets. Test results pointed out that the confinement provided by CFRP jacketing has remarkably improved the performance of seismically-deficient RC columns subjected to high axial compression under high shear demand in terms of lateral load capacity and ductility. The experimental results were also supplemented with theoretical work to evaluate the effects of CFRP jacketing on the seismic behavior of sub-standard RC columns.
Original language | English |
---|---|
Title of host publication | 10th International Conference on FRP Composites in Civil Engineering - Proceedings of CICE 2020/2021 |
Editors | Alper Ilki, Medine Ispir, Pinar Inci |
Publisher | Springer Science and Business Media Deutschland GmbH |
Pages | 1278-1290 |
Number of pages | 13 |
ISBN (Print) | 9783030881658 |
DOIs | |
Publication status | Published - 2022 |
Event | 10th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering, CICE 2021 - Virtual, Online Duration: 8 Dec 2021 → 10 Dec 2021 |
Publication series
Name | Lecture Notes in Civil Engineering |
---|---|
Volume | 198 LNCE |
ISSN (Print) | 2366-2557 |
ISSN (Electronic) | 2366-2565 |
Conference
Conference | 10th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering, CICE 2021 |
---|---|
City | Virtual, Online |
Period | 8/12/21 → 10/12/21 |
Bibliographical note
Publisher Copyright:© 2022, The Author(s), under exclusive license to Springer Nature Switzerland AG.
Funding
Acknowledgment. This project is supported by the Scientific and Technological Research Council of Turkey (TUBITAK) under the grant number 216M379 and the Research Councils of UK (RCUK) under the grant number EP/P010016/1. The authors would like to appreciate the support provided by Mr. M. Marasli and the Fibrobeton Company. The contributions of F. Narlitepe, N. Kian, E. Tore, M. C. Luleci, A. Baltaci, B.Sari, S. Gundogan are also gratefully acknowledged.
Funders | Funder number |
---|---|
TUBITAK | 216M379 |
Research Councils UK | EP/P010016/1 |
Türkiye Bilimsel ve Teknolojik Araştirma Kurumu |
Keywords
- CFRP
- Column
- Retrofitting
- Seismic
- Sub-standard